ESDMAN P/N: 001-9201 Single Operator Wrist Strap Monitor

  • Availability:In Stock
  • Product Code: #001-9201

ESDMAN P/N: 001-9201

Single Operator Wrist Strap Monitor

        * Descriptions

ESDMAN Constant Monitors meet the Continuous Monitor requirements of ANSI/ESD S20.20. “Typical test programs recommend that wrist straps that are used daily should be tested daily. However, if the products that are being produced are of such value that knowledge of a continuous, reliable ground is needed, and then continuous monitoring should be considered or even required.” (ESD Handbook ESD TR20.20 Wrist Strap section 5.3.2.4.4 Test Frequency)

·        Monitors can check up to two wrist strap systems and one work surface, depending on the model.

·        Compatible with single-wire wrist straps.

·        Easy to use: Simple plug in the wrist strap.

·        Easy to install: Attach the monitor boxes to the bench with included hardware, connect the mat and plug it in.

·        East to install: Attach the monitor boxes to the bench with included hardware, connect the mat and plug it in.

Damage to electronic devices is caused by static electricity from people. Connecting people to ground directs static electricity away from devices. Constant Monitors are designed to constantly test the connection of the person, the wristband and the coiled cord to help ensure that people remain grounded.

Constant Monitor 001-9201 uses a solid state impedance design to constantly test the connection integrity of the entire ground system including the person, the wristband and the coiled cord. Constant Monitors 001-9202 and 001-9203 also provide worksurface monitoring. This system is fully automatic and activates when a wrist strap is plugged into the unit. A green light indicates connection and a red light indicates there is no connection (disconnected status). The unit is powered and grounded by the AC adapter.


* Model for Options

Item

Operator(s)

Mat(s)

001-9201

1

0


* Calibration

The Constant Monitors are calibrated to standards traceable to NIST. Frequency of re-calibratrion should be based on the critical nature of those ESD sensitive items handled and the risk of failure for the ESD protective equipment and materials. In general, ESDMAN recommend that calibration be performed annually.

* Weights and Dimensions

Item

Dimensions

Weight

001-9201

    0.9” H x 1.8” W x 1.3” D

1.2 oz.


* Specifications

Monitor Type

Impedence – Single – wire

Circuitry

Solid-state, surface mount

Alarm

Audible and visible (LED)

Alarm Threshold

8 megaohms

Power

120VAC, 230VAC

Adjustments

None required